Daikin AlthermaAir-to-water
Indoor unitAnd outdoor unit
Price firstBefore the repair
22 yearsIn the trade
Underfloor heating being laidAir-to-water heat pump installed against a house

A Daikin Altherma in fault

The Daikin Altherma is one of the most widely installed air-to-water heat pumps in Belgium: Altherma 3 R, Altherma 3 H HT to replace a boiler on radiators, monobloc or split, with a wall-hung indoor unit or a floor-standing unit with a built-in tank.

A heat pump constantly monitors the water flow, the temperatures, the communication between the two units and the refrigerant circuit. The most common code is 7H-01, a lack of water flow. U4-00 reports that the indoor and outdoor units no longer talk to each other, 89-02 a frozen exchanger.

Our technician checks the flow, the strainer, the pump, the sensors, the power to both units and, if needed, the refrigerant circuit. He explains the cause and tells you what the repair costs before doing it.

Viessmann heat pump installed against a house

Codes 7H-01 to E1-00

7H-01 — Water flow problem in the heating circuit. Pressure, air, valves, strainer, circulating pump.

80-00 — Problem with the return water temperature sensor. Return sensor and wiring.

81-00 — Problem with the flow water temperature sensor. Flow sensor and wiring.

89-02 — Heat exchanger frozen (outside defrost). Water flow in cold weather, frost protection, settings.

8H-00 — Abnormal rise of the flow water temperature. Flow rate, flow sensor, electric back-up heater.

AA-01 — Electric back-up heater overheated. Back-up heater safety device, water flow, contactors.

E1-00 — Outdoor unit board fault. Outdoor unit board, power supply.

These codes apply to the Daikin Altherma 3; older Altherma units may show slightly different codes. Always note the two figures after the dash.

Air-to-water heat pump installed against a houseTechnician servicing a heat pump

Codes E3-00 to U5-00

E3-00 — High pressure switch tripped. Water flow, refrigerant circuit, heat exchanger.

E7-00 — Outdoor unit fan motor fault. Fan, blocked unit, board.

H9-00 — Outdoor temperature sensor fault. Outdoor unit sensor and wiring.

HC-00 — Domestic hot water sensor fault. Tank sensor and wiring.

U0-00 — Probable lack of refrigerant. Tightness of the refrigerant circuit, leak search.

U2-00 — Abnormal supply voltage. Electrical supply of the outdoor unit.

U4-00 — Communication lost between indoor and outdoor unit. Outdoor unit power, interconnection cable, boards.

U5-00 — Problem communicating with the user interface. Controller, controller cable, indoor unit board.

Your code is not listed? Call us: the technician knows it.

Indoor unit of a heat pump with a hot water cylinder

Servicing a Daikin heat pump

Many Altherma codes come from a lack of servicing: a dirty strainer (7H-01), an outdoor unit full of leaves (E7-00), settings that do not match the house.

During the service the technician cleans the strainer of the water circuit, checks the pressure and the expansion vessel, cleans the outdoor coil, checks the electrical connections and notes the operating values.

He also looks at the fault history in the controller: he can see whether a code comes back on cold nights and adjusts the settings so that the heat pump works in good conditions.

Technician servicing a heat pumpViessmann heat pump installed against a house

Typical faults

Water flow (7H-01): a dirty strainer, air in the circuit, a closed valve or a tired pump. Communication (U4-00, U5-00): an outdoor unit without power, a damaged interconnection cable or a faulty board.

Frost (89-02): too little flow in cold weather, the exchanger freezes and the unit protects itself. Keep the heat pump powered so that its frost protection keeps working.

Back-up heater (AA-01): the electric element overheated, often because of the flow. Refrigerant (U0-00): a small leak lowers performance and then stops the unit.

Underfloor heating being laid

What the technician does

He reads the fault history: the controller keeps the last codes with their time, so he sees what happens at night and in cold weather.

He measures both circuits: flow and pressure of the water circuit, temperatures and, if needed, the refrigerant pressures. Then come the price, the repair, the adjustment of the controls, the job sheet and the invoice.

A heat pump contains refrigerant under pressure and live parts: only a technician should open the indoor or outdoor unit.

Codes we see most

7H-01

Not enough water flow.

U4-00

No communication between units.

89-02

Frozen exchanger.

AA-01

Back-up heater overheated.

When you call

The full code

For example 7H-01.

The model

Altherma 3 R, H HT…

The pressure

Of the water circuit.

When

Day, night, in frost.

How we work

1

Phone, WhatsApp or online

Use whichever suits you and tell us your neighbourhood.

2

Time confirmed

You know when the technician will come and what the call-out costs in advance.

3

Nothing without your OK

Work starts once you have said yes. Keep the job sheet and the invoice for your records.

What our customers say

Where we work

We repair and service Daikin heat pumps across Belgium, in Brussels, Flanders and Wallonia.

BrusselsWalloon BrabantFlemish BrabantHainautNamurLiègeLuxembourgAntwerpEast FlandersWest FlandersLimburg

Frequently asked questions

What does code 7H-01 mean on a Daikin Altherma?

The water flow in the heating circuit is too low. The strainer, air in the installation, a valve or the pump can be the cause: note the code and call us.

What does U4-00 mean?

The indoor unit no longer communicates with the outdoor unit. The power to the outdoor unit, the interconnection cable or a board needs checking.

My Altherma shows 89-02 in frosty weather: what do I do?

The exchanger has frozen and the unit is protecting itself. Keep the heat pump powered and call us: the cause is often a flow that is too low.

Is code AA-01 serious?

The electric back-up heater overheated and its safety device cut out. The cause has to be found before it goes back into service: that is a job for the technician.

Do you service Daikin heat pumps?

Yes: water circuit strainer, outdoor unit, connections, operating values and controller settings.

When can you come?

We offer the first free slot, depending on your municipality, with the price given first.

How do I book?

Call 0477 03 88 98, send us a WhatsApp message or book online with the « Book an appointment » button. Tell us the municipality and, in a few words, what is going on.

Is your Daikin Altherma showing a code?

Call 0477 03 88 98 or book online: a technician comes to check your heat pump.