Failed ignition (E01)
Worn or misaligned electrode, low gas pressure, tired gas valve: the most common code in winter.
Home › Heating › Error codes › ACVService 7 days a week
Has your ACV boiler (Prestige, HeatMaster, Delta…) stopped with a code beginning with "E"? The table below gives the meaning of the codes shown by the ACVMax control. These Belgian boilers, often with a built-in hot water tank, need an engineer who knows them: we come out 7 days a week and tell you the price before the repair.
★★★★★5,0on Google22 years of experiencePrice agreed before the work

ACV is a Belgian manufacturer that has been based near Brussels for decades. Its Prestige condensing boilers and its HeatMaster units with an integrated cylinder are found in many homes and small buildings across the country, running on gas or on oil. Their "tank-in-tank" design, a hot water cylinder immersed in the heating water, makes them very comfortable but also rather different from ordinary wall-hung boilers.
When the ACVMax control detects a fault, it shuts the burner down and displays a code: E01 for a failed ignition, E03 for excessive temperature, E05 for a fan running at the wrong speed. Some codes clear by themselves once the cause disappears, others lock the appliance until someone intervenes.
Our engineer reads the fault memory, measures the ionisation current and the gas pressure, tests the flow and return sensors, then explains what he found and the cost of the repair before carrying it out. On a HeatMaster he also looks at the inner tank and its safety devices.

A Prestige that frequently shows E01 or E02 nearly always has a fouled electrode or a burner in need of cleaning. On oil models, a worn nozzle or a clogged filter cause the same symptoms. Regular servicing removes most of these stoppages.
During the service the technician dismantles and cleans the burner, inspects the heat exchanger, sets the combustion with an analyser and checks the condensate trap. You then receive the service attestation required for your boiler.
He also notes the codes stored in memory: a string of lockouts since the last visit is a warning sign worth taking seriously, especially before winter.

On a Prestige with the ACVMax control, the fault appears as the letter E followed by two digits, with a flashing symbol. On an older HeatMaster or a Delta with an oil burner, the display may stay blank while a red lamp on the burner itself lights up. Note what you see on both: the screen and the burner.
Take a photo of the screen and of the rating plate, usually at the bottom of the casing. Send both by WhatsApp or read them out when you call 0477 03 88 98: with the model and the code, the engineer knows which parts to bring.

Many rented flats in Brussels have an ACV combi or a HeatMaster in the kitchen cupboard. Under most Belgian leases, the tenant books and pays the regular service, while the landlord pays for major repairs and replacement. If a code keeps coming back, report it to your landlord or agent in writing, with the code and the date.
After every visit, our engineer leaves a written report that you can forward to the landlord. It says what was found and what was done, which settles most discussions about who pays.
These codes apply to ACV boilers fitted with the ACVMax control (recent Prestige models). Older generations and oil boilers with a separate burner may display things differently: write down what the screen shows and call us.
| Code | Meaning | What the technician checks |
|---|---|---|
| E01 | Ignition failure: the burner did not light after 5 attempts | Gas supply, ignition electrode, ignition lead, gas valve. |
| E02 | False flame: a flame is detected before ignition | Fouled electrode, earthing, control board. |
| E03 | Boiler temperature too high | Water circulation, circulating pump, flow sensor, heat exchanger. |
| E05 | Incorrect fan speed or no speed signal | Fan, wiring and connectors, ACVMax board. |
| E08 | Flame circuit error (test failed) | Flame detection circuit and control board. |
| E09 | Gas valve circuit error (test failed) | Gas valve, gas valve wiring, control board. |
| E12 | Internal fault: wrong memory configuration (EEPROM) | Control settings, board replaced if necessary. |
| E13 | Maximum number of restarts reached | Cause of the repeated lockouts: the original fault is traced. |
| E16 | Flow sensor stuck: its value no longer changes | Flow sensor, contact with the pipe, wiring. |
| E17 | Return sensor stuck: its value no longer changes | Return sensor and its wiring. |
| E18 | Sensor fault: flow or return value changes too fast | Sensors, water circulation, air in the system. |
| E19 | Flame lost during the start-up phase | Gas pressure, ionisation electrode, combustion setting. |
| E25 | Internal control fault (CRC check) | ACVMax circuit board. |
Code not in this table: call us, our technician knows it.
Smell of gas? Do not touch any switch, open the windows, leave the house and call 112 from outside. For an E code, note it exactly, digits included, before calling: the technician prepares the matching parts.
Worn or misaligned electrode, low gas pressure, tired gas valve: the most common code in winter.
The heating water no longer flows enough: seized pump, closed valves or sludge in the system.
Worn bearings or an oxidised connector: the fan no longer reaches the speed the control asks for.
A loose sensor or a damaged cable distorts the reading and causes repeated stops.
On a HeatMaster, lukewarm hot water often comes from scale or a badly set valve.
The list of recent codes shows whether the fault is a one-off or has been coming back for weeks.
Ionisation, gas pressure, fan speed, sensor values: each part is tested before it is changed.
Price announced first, repair, analyser setting, then job report and invoice.
Publié sur Bob BlommaertTrustindex vérifie que la source originale de l'avis est Google. Super quick intervention on a late Tuesday evening!Publié sur Felix RathjeTrustindex vérifie que la source originale de l'avis est Google. Top service. Very professional. Clear communication and no sneaky sales pitches. Problem identified, problem solved. Correct!Publié sur Sébastien CharlesTrustindex vérifie que la source originale de l'avis est Google. Très content du service : communication via emails, entretien de la chaudière avec photos avant/après. Je recommande !Publié sur Radoua ChaaraTrustindex vérifie que la source originale de l'avis est Google. Very professional and fast service!! TopPublié sur Alae EabdenbitsenTrustindex vérifie que la source originale de l'avis est Google. Very nice of plumbing thanks a lot!
Our heating engineers work on ACV boilers throughout Belgium: in Brussels, in Wallonia and in Flanders. Tell us your code and your town, and we will give you a possible arrival time.
Our technicians work on all brands: they install, service and repair appliances from the major manufacturers. For a new installation, we recommend the model that suits your home and budget.
We buy our equipment from all the major Belgian wholesalers and suppliers, including Facq, Van Marcke and Desco: genuine parts, quickly available.
The burner did not light after five attempts. The cause may be the gas, the electrode, the ignition lead or the gas valve: the technician finds it by measuring.
It reports an excessive temperature inside the boiler. The boiler protects itself, but the reason the water no longer circulates must be found before it runs again.
The control has counted too many restarts in a short time. It is not the fault itself: the original problem is still there. Write the code down and call us.
Yes, gas and oil HeatMasters as well as wall-hung and floor-standing Prestige models, for repairs and servicing.
Note what the screen shows, or whether it is blank, and call us: a power supply or board fault can prevent the display from working.
Usually the tenant pays for servicing and small repairs, and the landlord for major parts and replacement. Your lease decides in the end; our written report helps you show what was wrong.
Yes, by WhatsApp or e-mail. A photo of the display and of the rating plate is often enough for the engineer to prepare the right parts.
We offer the first available slot depending on where you live. The price is given before any work.
Call us or pick a time online: a heating engineer who knows ACV boilers comes to your home.