De DietrichGas and oil
7 days a weekEvenings and weekends
DiagnosisBy measurement
QuoteFree for a new boiler
Oil-fired boiler in a boiler room

De Dietrich boilers: gas, oil and floor-standing

The French-German brand De Dietrich is known in Belgium for two very different families. On one side, the wall-hung condensing gas boilers such as the Naneo and Evodens. On the other, the robust cast-iron floor-standing boilers, often running on oil, that equip many detached houses.

The wall-hung models of the latest generation display a letter followed by four digits. The letter matters: H is a blocking that clears itself when conditions return to normal, E is a lockout that keeps the boiler off. The failed start E04.10 is the one we are called for most.

Floor-standing oil boilers and older De Dietrich control panels (Diematic) show their faults differently. Our engineers know these installations and read the information on site, whatever the age of the boiler.

Combustion analysis during a boiler service

Measuring before repairing

For each code, the technician starts with measurements: gas or oil pressure, ionisation current, flow and return temperatures, fan speed, combustion values. Only then does he decide which part is at fault.

You are told what he has found and the price of the repair before he starts. When the yearly service is due, he cleans the boiler, analyses the combustion and leaves the service attestation.

Technician servicing an oil-fired boiler

How to read a De Dietrich code: H, E and the numbers that follow

On recent De Dietrich boilers, such as the Naneo, the Innovens and the MCR range, the display shows codes that start with a letter followed by numbers, like H.01.05 or E.04.10. As a rule of thumb, an H code is a temporary block: the boiler waits until the cause disappears and then restarts by itself. An E code is a lockout: the boiler stays off until it is reset.

Before you call, note the exact code, the model and, if you can find it, the serial number on the data plate behind the front panel. Look at the pressure gauge too: many De Dietrich codes simply come from low water pressure in the system. If the boiler is a condensing model and it is freezing outside, check whether the condensate pipe has frozen.

You may reset a lockout once. If the same code comes back straight away, leave it to an engineer. De Dietrich and Remeha share many parts and codes, so the explanations on Remeha error codes can also help.

Technician checking a plan on a tablet in a plant room

When a code keeps coming back: what the engineer checks

A code that returns again and again almost always points to a part that is wearing out. On De Dietrich gas boilers we often find a dirty condensate trap, a worn ignition electrode, a weak flame signal, a fan that no longer reaches its speed or a heat exchanger fouled on the flue side. On oil boilers, the burner is usually the cause: nozzle, filter, photocell or pump.

The engineer reads the fault history so he also sees codes you may have missed, then cleans, tests and replaces only what is really faulty. After the repair he measures the combustion, so the boiler is not only running again but also burning cleanly. For a boiler that is no longer worth repairing, he explains the options honestly.

For an engineer who knows the brand, see heating engineer De Dietrich, and for other brands boiler error codes. For a De Dietrich showing a code in Brussels, Wallonia or Flanders, call 0477 03 88 98.

Common De Dietrich error codes

Codes of the recent De Dietrich wall-hung boilers. Search for yours; for older models and oil boilers, call us and the engineer will read the fault on site.

CodeMeaningWhat the technician checks
H02.02Waiting for the configuration numberConfiguration numbers CN1 / CN2, typically after a board has been changed.
H02.03Configuration errorConfiguration numbers, control board.
H02.04Parameter errorParameter settings, control board.
H02.05Memory unit (CSU) does not match the control unit (CU)Memory unit and control board.
H01.05Maximum difference between flow and return temperature exceededCirculation in the heating circuit, pump, sensors.
H01.08Heating flow temperature rising too fastPump, circulation, air in the system.
H01.14Maximum flow temperature exceededPump, circulation, flow sensor.
E04.08Safety input openSafety devices wired to the input.
E04.10Burner failed to start after five attemptsGas supply, ignition electrode, gas valve, flue, siphon.
E04.12False flame signalIonisation electrode, wiring, gas valve.
E04.13Fan blade stalledFan and wiring.
E04.17Gas valve driver faultGas valve, control board.

Code not in this table: call us, our technician knows it.

Smell of gas? Do not touch any switch, open the windows, leave the house and call 112 from outside. For any other code, write it down and call us: the technician knows what to look at and brings the right parts.

Faults we often see on De Dietrich boilers

Burner will not start

E04.10 on gas models, burner lockout on oil models: fuel supply, electrodes, nozzle or gas valve.

Overheating protection

H01.05, H01.08 or H01.14: the water does not circulate well enough. Pump, valves and air in the circuit are examined.

After a board replacement

H02.02 to H02.05: the new electronics are not configured yet. The engineer enters the right configuration.

Old installations

Ageing cast-iron boilers and Diematic panels: repair when it makes sense, free quote for a replacement when it does not.

What our customers say

Where do we work?

De Dietrich boilers are repaired and serviced by our engineers everywhere in Belgium, from Brussels to Wallonia and Flanders. Call us to know when a technician can come round.

BrusselsWalloon BrabantFlemish BrabantHainautNamurLiègeLuxembourg provinceAntwerpEast FlandersWest FlandersLimburg

The brands we work with

Our technicians work on all brands: they install, service and repair appliances from the major manufacturers. For a new installation, we recommend the model that suits your home and budget.

De DietrichRemehaViessmannBuderusVaillantBoschWolfAtlanticElcoWeishauptRiello

We buy our equipment from all the major Belgian wholesalers and suppliers, including Facq, Van Marcke and Desco: genuine parts, quickly available.

FacqVan MarckeDesco

Also worth a look

Frequently asked questions

What does E04.10 mean on a De Dietrich boiler?

The burner did not start after five attempts and the boiler locked out. The gas supply, the ignition electrode, the gas valve, the flue and the siphon are the parts inspected.

Are De Dietrich and Remeha codes identical?

For the recent wall-hung boilers, largely yes: both brands belong to the same group and use the same electronics.

My De Dietrich runs on oil: are the codes the same?

No. Oil boilers have a burner with its own control box and show faults differently. Our engineers repair them too.

What does H01.08 mean?

The flow temperature is rising too quickly, usually because water is not circulating well. The boiler waits before starting again.

What should I do when a code appears?

Note it and call us. Repeated lockouts point to a fault that needs a diagnosis, not to more restarts.

My De Dietrich shows an H code and restarts on its own. Is that a problem?

An H code that appears now and then and disappears is usually a temporary block, for example after a short pressure drop. If it happens every day, ask an engineer to look at the cause before it turns into a lockout.

Can you repair an old De Dietrich oil boiler?

Yes. We service and repair De Dietrich floor-standing oil boilers. Most burner parts are easy to find in Belgium; for a very old boiler we tell you beforehand if a part is hard to get.

Do you give quotes for a new boiler?

Yes. If your De Dietrich is no longer worth repairing, we visit and give you a free quote for a boiler or a heat pump.

Your De Dietrich shows a code?

Call us or book online: a heating engineer comes to your home with his measuring equipment.