Overheat
Water too hot: seized pump, circulation cut off, all radiators closed. A high-limit thermostat shuts the burner off.
Home › Boiler lockout
Your boiler locks out, a red light comes on and it asks to be reset, sometimes several times a day? A lockout is not the fault itself: it is the boiler protecting you. Our engineers find what triggers it and repair it, 7 days a week.
★★★★★5,0on Google· 22 years of experience

The most common lockout is flame failure. At each start the boiler opens the gas, makes a spark and must detect a flame within a few seconds. If it does not, it shuts the gas and locks out: code F28 or F29 on Vaillant, 6A on Buderus, E133 on Remeha.
The causes are well known: insufficient gas supply, worn ignition electrode, dirty flame sensor, poor earth or a faulty gas valve. A boiler that locks out mainly in the morning or in hard frost may also have a frozen condensate pipe.
The engineer measures the gas pressure during ignition and the flame current. Those two figures often point to the faulty part. He cleans or replaces it and restarts the boiler several times to check it lights every time.

Boilers also monitor the removal of combustion gases. A pressure switch or flue thermostat shuts the appliance down if the gases are not leaving properly. It is an essential protection against carbon monoxide.
A flue blocked by a nest, debris or soot, an iced-up wall terminal, a dirty fan or a split pressure switch tube trigger this safety. Sometimes it only happens in strong winds, when air pushes back down the flue.
The engineer checks the fan, the pressure switch and the draught, then carries out a combustion analysis in the flue. If the flue itself needs cleaning or modifying, he tells you clearly. Never bypass this safety device: it is there for your health.


On an oil boiler, a lockout shows as the red light on the burner. The burner tried to start, the photocell saw no flame and it stopped. It happens after running out of oil, with a blocked filter, a clogged nozzle or a sooty photocell.
You may press the reset button once. If the burner locks out again, do not keep trying: atomised oil that did not burn builds up and makes the next ignition dangerous.
The technician cleans the photocell, checks the oil pump and suction line, replaces the nozzle and filter if needed and adjusts the burner. If the lockout came from an empty tank, he advises having the filter checked after the delivery.
Not all boilers have the same protections, but these are found on almost all of them.
Water too hot: seized pump, circulation cut off, all radiators closed. A high-limit thermostat shuts the burner off.
Below about 0.8 bar the boiler stops so as not to run dry. Bring the pressure to 1.5 bar when cold.
The condensate trap is full or frozen: the boiler shuts down before water reaches the combustion chamber.
A temperature sensor giving a wrong reading makes the boiler think it is overheating.
Live and neutral swapped, or a missing earth, stop some boilers detecting the flame.
Give us the code shown and tell us when the boiler locks out.
The engineer measures gas, flame, flue and circulation, then gives the repair price.
He repairs, runs several cycles, checks the combustion and hands you the job sheet.
Publié sur Bob BlommaertTrustindex vérifie que la source originale de l'avis est Google. Super quick intervention on a late Tuesday evening!Publié sur Felix RathjeTrustindex vérifie que la source originale de l'avis est Google. Top service. Very professional. Clear communication and no sneaky sales pitches. Problem identified, problem solved. Correct!Publié sur Sébastien CharlesTrustindex vérifie que la source originale de l'avis est Google. Très content du service : communication via emails, entretien de la chaudière avec photos avant/après. Je recommande !Publié sur Radoua ChaaraTrustindex vérifie que la source originale de l'avis est Google. Very professional and fast service!! TopPublié sur Alae EabdenbitsenTrustindex vérifie que la source originale de l'avis est Google. Very nice of plumbing thanks a lot!
Our heating engineers work all over Belgium: Brussels, Flanders and Wallonia. For a boiler in lockout, call us to find out the first available visit.
Our technicians work on all brands: they install, service and repair appliances from the major manufacturers. For a new installation, we recommend the model that suits your home and budget.
We buy our equipment from all the major Belgian wholesalers and suppliers, including Facq, Van Marcke and Desco: genuine parts, quickly available.
The safety device is doing its job. What matters is the reason: one isolated reset is not worrying, repeated lockouts mean a part needs repairing.
Once. If it locks out again, stop and call us on 0477 03 88 98. Repeated resets can make the fault worse, especially on oil.
Often a condensate pipe that freezes overnight, or harder ignition when everything is cold. The engineer checks the drain and the ignition.
No, never. A disabled safety device can cause overheating, an explosion or carbon monoxide poisoning.
It prevents many: clean electrodes and burner, cleared trap and correct combustion. It is the best prevention.
Yes: Vaillant, Bulex, Viessmann, Buderus, Remeha, Junkers, Saunier Duval, ACV, Atag, Intergas and others, gas and oil.
It depends on the cause: cleaning a sensor is quick, a gas valve or a board costs more. The engineer gives you the price after the diagnosis and before starting the repair.
Call us for a repair, book a slot online or request a quote.