A codes: lockout
The boiler is locked and stays off. The cause (flame, overheating) needs a diagnosis by an engineer.
Home › Heating › Error codes › Ferroli
Your Ferroli Bluehelix, Divacondens or Domiproject boiler shows A01, F37 or another code? The table explains the common Ferroli codes. With Ferroli, a code starting with A is a lockout that keeps the boiler stopped, while an F code is a fault that may clear once its cause disappears. We repair Ferroli boilers 7 days a week with the price given first.
★★★★★5,0on Google· 22 years of experience


The Italian manufacturer Ferroli sells compact condensing combi boilers that are often chosen for flats and small houses. The Bluehelix and Divacondens ranges are the most common today; many older Domiproject and Domina boilers are still running.
The code we are called for most is A01: the burner did not light and the boiler locked out. Next comes F37, a water pressure that is too low, followed by sensor faults (F10, F11) and overheating (A03).
Codes F34 and F35 are worth knowing: they do not point to the boiler itself but to its power supply, which can be disturbed by a weak line or another appliance.

Our engineer reads the code, measures gas pressure, ionisation and temperatures, tests the pump and the pressure sensor, and only then decides which part is responsible. You are told the price of the repair before he starts.
The yearly service keeps A01 and A06 lockouts away by cleaning the burner, inspecting the electrode and the condensate siphon and analysing the combustion. You receive the service attestation afterwards.
The Ferroli codes we see most. Search for yours in the box; any other code, give it to us by phone.
| Code | Meaning | What the technician checks |
|---|---|---|
| A01 | Burner does not light: no flame detected (lockout) | Gas supply, ignition and detection electrode, gas valve. |
| A02 | Flame signal while the burner is off | Electrode, wiring, circuit board. |
| A03 | Overheating protection triggered | Circulation, pump, air in the circuit, flow sensor. |
| A06 | No flame after the ignition phase | Gas pressure, minimum gas setting, electrode. |
| F10 | Flow sensor 1 fault | Flow sensor and its wiring. |
| F11 | Hot water sensor fault | Hot water sensor and its wiring. |
| F14 | Flow sensor 2 fault | Second flow sensor and its wiring. |
| F34 | Supply voltage below 180 V | Electrical supply to the boiler. |
| F35 | Abnormal mains frequency | Electrical supply to the boiler. |
| F37 | Incorrect system water pressure (too low) | Circuit pressure, leaks, pressure sensor. |
| F39 | Outdoor sensor fault | Outdoor sensor and its cable. |
| F40 | System water pressure too high | Filling, expansion vessel, pressure sensor. |
Code not in this table: call us, our technician knows it.
Smell of gas? Do not touch any switch, open the windows, leave the house and call 112 from outside. For any other code, write it down and call us: the technician knows what to look at and brings the right parts.
The boiler is locked and stays off. The cause (flame, overheating) needs a diagnosis by an engineer.
A sensor, the pressure or the power supply is out of range. Some clear by themselves when the condition returns to normal; if not, the part is tested.
A code that keeps coming back always hides a real cause. Note it and call us.
Model and code on the display. We plan the visit and the parts.
The engineer confirms the cause with his instruments before any replacement.
Price announced first, repair, test, job report and invoice.
Publié sur Bob BlommaertTrustindex vérifie que la source originale de l'avis est Google. Super quick intervention on a late Tuesday evening!Publié sur Felix RathjeTrustindex vérifie que la source originale de l'avis est Google. Top service. Very professional. Clear communication and no sneaky sales pitches. Problem identified, problem solved. Correct!Publié sur Sébastien CharlesTrustindex vérifie que la source originale de l'avis est Google. Très content du service : communication via emails, entretien de la chaudière avec photos avant/après. Je recommande !Publié sur Radoua ChaaraTrustindex vérifie que la source originale de l'avis est Google. Very professional and fast service!! TopPublié sur Alae EabdenbitsenTrustindex vérifie que la source originale de l'avis est Google. Very nice of plumbing thanks a lot!
Ferroli boilers are repaired and serviced by our engineers throughout Belgium: Brussels, Wallonia and Flanders. Call us and we will tell you the first time a technician can come.
Our technicians work on all brands: they install, service and repair appliances from the major manufacturers. For a new installation, we recommend the model that suits your home and budget.
We buy our equipment from all the major Belgian wholesalers and suppliers, including Facq, Van Marcke and Desco: genuine parts, quickly available.
The burner did not light and the boiler has locked out. Gas supply, ignition electrode, flame detection and gas valve are inspected.
The water pressure in the heating system is not correct, usually too low. A pressure that keeps falling points to a leak or a faulty part.
The overheating protection has tripped. The water is not circulating well enough: pump, air in the circuit or flow sensor must be examined.
The supply voltage is too low (F34) or the mains frequency is abnormal (F35). The electrical supply to the boiler is examined.
Write it down and call us. Repeated restarts will not repair the boiler.
Yes, all Ferroli gas boilers, with cleaning, combustion analysis and the service attestation.
Call us or pick a time online: a heating engineer comes to find and repair the fault.